Windows & doors · uPVC windows

Why Is My uPVC Double Glazing Misted or Foggy Between the Panes?

For a double-glazed uPVC window where mist, fogging, droplets or a cloudy film are trapped between the two panes rather than forming on the room-side surface.

Quick answer

What this usually means

Condensation trapped between the panes usually means the sealed insulating glass unit has failed and moisture has entered the cavity. The Glass and Glazing Federation distinguishes this from ordinary room-side condensation and explains that a failed sealed unit can normally be replaced without replacing the whole window frame. Check that the moisture really is between the panes and not on an accessible surface. If it is internal to the glass unit, cleaning will not remove it; a glazing specialist should measure and replace the sealed unit.

Likely causes

What may be causing this

1

The edge seal of the insulating glass unit has failed

Clues: Fogging is clearly trapped between panes and cannot be wiped from either accessible face.

What to do: Have the sealed glass unit measured and replaced.

2

The glass unit has been damaged or its edge has deteriorated

Clues: The misting follows impact, frame movement or long-term water exposure around the glazing system.

What to do: Have the glass and glazing pocket inspected for the cause as well as replacing the unit.

3

Ordinary surface condensation is being mistaken for failed double glazing

Clues: The moisture wipes away from the room-side or exterior surface.

What to do: Treat the indoor-humidity or exterior-condensation cause rather than replacing the glass.

Diagnose the pattern

How to check what is happening

Wipe both accessible glass faces
The cloudy area remains between the panes

The sealed unit itself has likely failed.

Look for the fogging pattern over several days
It changes with weather but never wipes away

Moisture is trapped inside the insulating glass cavity.

Inspect the frame and glazing externally from a safe position
There is obvious damage or failed surrounding weatherproofing

The cause should be corrected when the sealed unit is replaced.

DIY decision

Can you fix this yourself?

Confirm the mist is genuinely between the panes. Replacing an insulating glass unit requires correct measurement, glazing practice and safe handling of glass.

You'll usually need:
  • Soft cloth
  • Phone camera
  • Window specification if available
Step by step

What you can safely try

  1. 1

    Confirm where the condensation is

    Wipe the inside and outside surfaces to make sure the moisture is trapped within the sealed unit.

  2. 2

    Record the affected pane

    Photograph the misting and any visible frame or seal damage for the glazier.

  3. 3

    Arrange sealed-unit replacement

    A glazier can usually replace the glass unit while retaining a sound uPVC frame.

Stop conditions

Call a glazier if…

  • The glass is cracked, chipped or unstable.
  • The pane is at height or unusually large and cannot be inspected safely.
  • Removing glazing beads or the glass would be required.
Still need help?

Get the right glazier.

We already know this problem maps primarily to a glazier. Choose the closest type of work, add your postcode and continue in the form.

Find a glazier →
Evidence

Sources used for this guide

We prefer primary UK guidance, regulators and manufacturers for technical and safety-sensitive claims.

  1. Condensation in double glazingGlass and Glazing Federation
  2. When to repair or replace your windowsGlass and Glazing Federation

Last reviewed: 6 September 2026. Home Manual updates review dates only when the substance of a guide is checked or changed.

Get a glazier