Why Can I Feel a Draught Around My Double-Glazed Window When It Is Closed?

For a closed double-glazed window that still lets in a noticeable cold draught around the sash, frame or surrounding seal, without the window being visibly open.

Quick answer

What this usually means

A draught from a closed double-glazed window usually means air is passing through a gap around the opening sash, seals, frame junction or installation perimeter. Everest describes air leakage around frames and weak seal points as a key part of window performance. A failed sealed glass unit causes insulation loss and may mist between panes, but a felt draught is more often about an air path around the frame or opening section.

Likely causes

What may be causing this

1

The opening-sash seals are not compressing evenly

Clues: The draught is strongest along one edge and changes when you press the closed sash gently toward the frame.

What to do: Have sash alignment, hinges, locking points and replaceable seals checked.

2

The perimeter seal between frame and wall has opened

Clues: Air is felt around the outer frame or reveal rather than the opening sash.

What to do: Inspect room-side sealant for visible gaps and have failed perimeter sealing repaired appropriately.

3

The frame or sash has distorted or become misaligned

Clues: The window is also stiff, catches, needs force to lock or has uneven gaps.

What to do: Arrange adjustment or repair rather than forcing the handle.

Diagnose the pattern

How to check what is happening

Move a hand slowly around the closed sash from the room side
One edge is noticeably colder or moving air can be felt

The local seal or sash compression is a likely air path.

Check the frame-to-wall joint
There are visible cracks or gaps in perimeter sealant

Air may be bypassing the window through the installation joint.

Open and close the window normally
It catches, needs force or the handle is difficult to lock

Alignment or hardware problems may be preventing even sealing.

DIY decision

Can you fix this yourself?

Room-side checks can narrow the air path. Cleaning accessible seals and removing debris is reasonable, but adjustment, gasket replacement or frame sealing should be done without compromising drainage slots or the locking system.

You'll usually need:
  • Torch
  • Tissue strip for locating gentle air movement
  • Soft cloth
Step by step

What you can safely try

  1. 1

    Clean the accessible seals and frame

    Dirt or trapped debris can stop a sash closing consistently against its seals.

  2. 2

    Inspect the room-side perimeter seal

    Look for obvious cracks or gaps where the frame meets the plaster or trim.

  3. 3

    Check whether the sash closes and locks normally

    A stiff or misaligned window often needs hardware adjustment rather than extra sealant.

Stop conditions

Call a window fitter if…

  • The window cannot be locked securely.
  • The sash is visibly distorted or loose.
  • There is water ingress as well as the draught.
  • The problem is on an upper-storey exterior side that cannot be checked safely.
  • Seals or hardware need dismantling to diagnose the fault.
Still need help?

Get the right window fitter.

We already know this problem maps primarily to a window fitter. Choose the closest type of work, add your postcode and continue in the form.

Find a window fitter →
Evidence

Sources used for this guide

We prefer primary UK guidance, regulators and manufacturers for technical and safety-sensitive claims.

  1. Energy Efficient WindowsEverest
  2. How Long Does Double Glazing Last?Everest

Last reviewed: 2 September 2026. Home Manual updates review dates only when the substance of a guide is checked or changed.

Get a window fitter